Electrical

What does an EICR check?

An EICR checks the fixed electrics in your home, such as the wiring, consumer unit, sockets, light fittings, earthing and bonding, for anything dangerous or worn. A registered electrician inspects and tests it and records any faults with the codes C1, C2, C3 or FI.

An Electrical Installation Condition Report (EICR) is a health check for the electrics built into your home. It is sometimes called a periodic inspection or an electrical safety certificate. It does not cover appliances you plug in. It covers the fixed parts: the wiring, the consumer unit, sockets, switches, light fittings and anything wired in permanently, such as an electric shower.

Safety: An EICR must be carried out by a competent person, such as a registered electrician. Don't open the consumer unit or take covers off sockets and switches yourself. The only safe checks for a homeowner are resetting a tripped RCD or circuit breaker, unplugging appliances and changing the fuse in a plug. Keep away from any light, socket or switch that has got wet.

What does an EICR check in your home?

Electrical Safety First says a periodic inspection looks for four main problems:

  • Circuits or equipment that are overloaded.
  • Anything that could cause an electric shock or a fire.
  • Defective electrical work, including poor DIY.
  • Missing or inadequate earthing and bonding.

To do that, the electrician looks at the condition of the consumer unit and its circuit breakers and RCDs, the type and condition of the wiring, the state of sockets, switches and light fittings, and whether outdoor sockets have RCD protection. Which? says the earthing and bonding check covers the connections to metal gas and water pipes. The installation is checked against the current wiring regulations, BS 7671.

What happens during an EICR inspection?

NICEIC describes four stages:

  1. A visual inspection of the installation, looking for damage, wear and anything that doesn't meet the regulations.
  2. Testing with specialist instruments. This includes continuity, insulation resistance, polarity, earth fault loop impedance and RCD tests.
  3. Recording the results and giving each problem found a classification code.
  4. Issuing the written report, with an overall result of satisfactory or unsatisfactory.

The electrician doesn't usually open up every single accessory. Which? says they will check a sample of at least 10 percent of your sockets, lights, switches and other accessories. Any parts that can't be inspected, for example because furniture blocks access, should be written on the report as limitations. Electrical Safety First's guidance says the more limitations there are, the less the report actually covers, so read that section.

How long does an EICR take, and is the power turned off?

NICEIC says an inspection takes from a few hours for a small home. Which? gives rough guides of up to three hours for a one-bedroom property, up to four hours for two bedrooms and three to five hours for three bedrooms. Bigger or older homes can take longer.

Expect the power to be off for some of that time. Which? says the electrician needs to turn the power off before testing the wiring, and NICEIC says parts of the installation will be isolated during testing. It helps to switch off and back up computers beforehand, and to clear access to the consumer unit and as many sockets as you can.

What do the EICR codes C1, C2, C3 and FI mean?

Each problem the electrician finds is given a code. These definitions come from NICEIC and Electrical Safety First:

  • C1, danger present. There is a risk of injury and immediate action is needed. The electrician may make it safe before leaving, for example by switching off the faulty part.
  • C2, potentially dangerous. It isn't an immediate danger, but urgent remedial work is needed.
  • C3, improvement recommended. It isn't dangerous, but improving it would make the installation safer.
  • FI, further investigation. The electrician couldn't reach a conclusion during the inspection and something needs looking into further.

Safety: Don't ignore a C1 or C2 code. If the electrician has switched off a circuit because it is dangerous, leave it off until it has been repaired by a registered electrician.

When is an EICR satisfactory or unsatisfactory?

Electrical Safety First's best practice guide says that if any observation is coded C1 or C2, the overall result must be unsatisfactory. If the report only has C3 codes, it can still be satisfactory. GOV.UK guidance for landlords adds that FI items must also be investigated, so treat them as unfinished business rather than a pass.

An unsatisfactory report means remedial work is needed. Once the work is done, the electrician should give you paperwork showing it, such as a new satisfactory EICR or an Electrical Installation Certificate. Some remedial work, such as replacing a consumer unit or adding a new circuit, is notifiable under Part P of the Building Regulations. A registered electrician who belongs to a competent person scheme can self-certify it.

How often do you need an EICR?

Electrical Safety First recommends these maximum gaps between inspections:

  • Every 10 years for a home you own and live in.
  • Every 5 years for a rented home.
  • Before you sell a home, or when you buy one that has been lived in before.
  • When a property is being prepared for letting.

For owner-occupiers there is no legal requirement, but it is a sensible check when you buy a home or if you are worried about older wiring. Each report also gives a recommended date for the next inspection, so book your next one by then.

Do landlords legally need an EICR?

Yes. In England, GOV.UK guidance says landlords must have the electrical installation inspected and tested by a qualified, competent person at least every 5 years. If you let a home in Berkshire, these England rules apply. The landlord must give a copy of the report to existing tenants within 28 days, and to new tenants before they move in.

If the report shows C1 or C2 codes, or FI items, the work must be done within 28 days, or sooner if the report says so. The landlord then has 28 days to give written confirmation of the work to the tenant and the local council. Councils can fine landlords up to £40,000 for breaches. Our guide to when landlords need an EICR covers the rules in more detail.

Before booking, check the electrician is registered. Electrical Safety First and NICEIC both point to competent person schemes. You can confirm registration with the scheme operator, such as NICEIC or NAPIT, or on the government's Registered Competent Person register.

Find a local electrician

Common questions

Does an EICR check my appliances?

No. An EICR covers the fixed installation: wiring, the consumer unit, sockets, switches, light fittings and wired-in equipment such as electric showers. Appliances you plug in are not part of it.

Is an EICR the same as an electrical safety certificate?

People often call an EICR an electrical safety certificate, but it is really a report on the condition of an existing installation. New or rewired installations get a different document, an Electrical Installation Certificate (EIC).

Will a C3 code fail my EICR?

No. C3 means improvement is recommended but the item isn't dangerous. A report with only C3 codes can still be satisfactory. Only C1 or C2 codes make the overall result unsatisfactory, though any FI items still need investigating.

Do I need to be at home during an EICR?

It helps. Someone needs to let the electrician in and give access to every room, the consumer unit and as many sockets as possible. Anything they can't reach is recorded as a limitation, which means that part isn't covered by the report.

Want someone to sort it?

Start a quote and we'll look for a local match.

Start my quote
Get a quote